Hot air · ZDK series
ZDK Oil/Gas Fired Hot Blast Stove
Hot air for natural gas, diesel — 11 standard sizes.

- Standard sizes
- 11
- Fuel
- Natural gas · Diesel
Design
Hot air for natural gas, diesel.
- Medium
- Hot air
- Fuel
- Natural gas / LPG, Diesel / heavy oil
- Standard sizes
- 11 · ZDK5 – ZDK300
Every standard size of the ZDK series is listed in the parameter table below with output, pressure, fuel consumption, connections, dimensions and weight. Send your required output, pressure and fuel and we return a model selection, drawings and a quotation.
Technical parameters
ZDK series
Every standard size with output, pressure, fuel consumption, connections, dimensions and weight. Boilers are built to order — the quotation confirms the final figures.
Ask for drawings →Swipe the table for all sizes
| Model | ZDK5 | ZDK10 | ZDK20 | ZDK30 | ZDK40 | ZDK70 | ZDK100 | ZDK130 | ZDK190 | ZDK250 | ZDK300 |
| Project | |||||||||||
| Rated heating capacity(x 104kj/h) | 20.9 | 41.8 | 501.6 | 125.4 | 167.2 | 292.6 | 418 | 543.4 | 794.2 | 1045 | 1254 |
| Light oil consumption(kg/h) | 5 | 10 | 20 | 30 | 40 | 70 | 100 | 130 | 190 | 250 | 300 |
| Natural gas consumption(m3/h) | 6 | 12 | 24 | 35 | 47 | 82 | 118 | 153 | 224 | 294 | 353 |
| Hot output air diameter(mm) | 450 | 550 | 600 | 630 | 700 | 800 | 850 | 850 | 900 | 1000 | 1050 |
| Output capacity of hot air m3/h | 1018 | 2035 | 4070 | 6105 | 8140 | 14240 | 20350 | 26450 | 38660 | 50870 | 61050 |
| Model | ZDK350 | ZDK400 | ZDK600 | ZDK700 | ZDK800 | ZDK900 | ZDK1000 | ZDK1200 | ZDK2000 | ZDK3000 | |
| Project | |||||||||||
| Rated heating capacity(x 104kj/h) | 1463 | 1672 | 2508 | 2926 | 3344 | 3762 | 4180 | 5016 | 8360 | 12540 | |
| Light oil consumption(kg/h) | 350 | 400 | 600 | 700 | 800 | 900 | 1000 | 1200 | 2000 | 3000 | |
| Natural gas consumption(m3/h) | 411 | 471 | 706 | 824 | 941 | 1059 | 1176 | 1412 | 2353 | 3529 | |
| Hot output air diameter(mm) | 1300 | 1500 | 1550 | 1700 | 1840 | 2000 | 2100 | 2300 | 2800 | 3200 | |
| Output capacity of hot airm3/h | 71220 | 81400 | 122100 | 142400 | 162800 | 183150 | 203500 | 244200 | 407000 | 610500 | |
| Design thermal efficiency(%) | ZDK: ≥93–95; | ||||||||||
| Hot air temperature°C | ZDK≤1300°C ( MAX), | ||||||||||
| Fuel type | LPG,Natural gas, Light oil, heavy oil | ||||||||||
From Wilford’s published data sheet. Boilers are built to order — the quotation confirms the final figures.
Hot Blast Stoves
Related series
Quotation
Quote for the ZDK
Tell us the output, working pressure, fuel and application. An engineer replies with a model selection and a quotation.
- Phone+86-512-5679 1900
- WhatsApp+86 177 9859 7687
- Emailmanager@wilfordboiler.com