Output
0.35–14 MW
Working pressure
0.7–1 MPa
Standard sizes
13
Fuel
Natural gas · Diesel

Design

CWNS series hot water boiler is three-pass all wet back shell type structure.

Medium
Hot water
Fuel
Natural gas / LPG, Diesel / heavy oil
Output
0.35–14 MW
Working pressure
0.7–1 MPa
Standard sizes
13 · WNS0.35 – WNS14

Main body includs boiler shell, furnace, boiler smoke chamber and convection bank. convection smoke tube is made by threaded pipes, enhance heat transfer. More than 90% thermal efficiency. Intelligent, fully automatic control, over-temperature stand by.

Address:9na Calle Poniente y 4ta Ave. Norte # 2-14C, Santa Tecla, La Libertad EI Salvador

Features

Swipe →
  1. 01 / 05

    CWNS series hot water boiler is three-pass all wet back shell type structure. Main body includs boiler shell, furnace, boiler smoke chamber and convection bank. convection smoke tube is made by threaded pipes, enhance heat transfer.

  2. 02 / 05

    Big furnace, high radiation area, three return design, full air combustion, good usage of heating surface. Smoke tubes add disturb fins inside, increasing heating area, self-clean for dust, improving heat transfer effectiveness. Using high thermal resistance of insulation materials-minimum boiler heat losses.

  3. 03 / 05

    More than 90% thermal efficiency. Intelligent, fully automatic control, over-temperature stand by. Anti-freezing in cold winter night, automatic adjust heating supply temperature base on out door temperature, which, maximum achieve energy saving.

  4. 04 / 05

    Imported burner, pressure spray, complete burning, low noise. Reduced combustion intensity, decrease dust emissions, output of harmful gases such as NOx emissions reduced to the minimum, meet serious environmental requirements.

  5. 05 / 05

    Pressure connecting structure, safe, reliable, long service life. Multiple chain protection and self-test such as -over temperature, water shortage, overload, ignition failure, abnormal flameout, gas leakage. Expansion water tank directly connect to atmosphere, no potential safety problems under atmospheric pressure operation.”

Technical parameters

WNS series

Every standard size with output, pressure, fuel consumption, connections, dimensions and weight. Boilers are built to order — the quotation confirms the final figures.

Ask for drawings →

Swipe the table for all sizes

WNS Horizontal Oil (gas) Fired Pressure Hot Water Boiler
ModelWNS0.35-0.7-95/70-Y(Q)WNS0.48-0.7-95/70-Y(Q)WNS0.7-0.7-95/70-Y(Q)WNS1.05-1.0-95/70-Y(Q)WNS1.4-1.0-95/70-Y(Q)WNS2.1-1.0-115/70-Y(Q)WNS2.8-1.0-115/70-Y(Q)WNS3.5-1.0-115/70-Y(Q)WNS4.2-1.0-115/70-Y(Q)WNS5.6-1.0-115/70-Y(Q)WNS7-1.0-115/70-Y(Q)WNS10.5-1.0-115/70-Y(Q)WNS14-1.0-115/70-Y(Q)
ItemUnit
Rated thermal powerMW0.350.480.71.051.42.12.83.54.25.6710.514
The working pressureMPa0.70.70.71111111111
The water temperature℃959595115115115115115115115115115115
Return water temperature℃70707070707070707070707070
Design the thermal efficiency%93.4393.5192.9493.0993.0093.0094.059494.0694.1594.0294.194.12
Water capacityL152017601950252029304300582080001086013500155002400026000
Water outletmm50658080100100150150200200200250250
Feed water inletmm50658080100100150150200200200250250
Drain valvemm4040405050505050505050*350*350*3
Chimneymm22022028033033040045050060065075010001200
SizeLengthmm2450275030503200350039004350540055005900680080008400
Widthmm1450145014801690169018002160224023802450270031003200
Heightmm1800180019702270227025042578260028803050310036004200
Size of baseLengthmm2000220025002700295035803850496049605720640075008000
Widthmm9009009001300130014001600170018002000210023002400
Fuel consumptionN.GNm³/H38.2452.476.89115.16153.69228.44303.96367.8455.88607.3735.31193.71452
Light oilKG/H31.5643.2863.5695.18127.07188.45250.79326.6377.46501.5633.2985.11258
City gasNm³/H81.26111.35163.4244.72326.6485.35645.9824968.71290163025363146
Transport weightkg30003500400046006000760010000120001500018600236003400041000

From Wilford’s published data sheet. Boilers are built to order — the quotation confirms the final figures.

Oil & Gas Fired Boilers

Related series

All oil & gas fired boilers →

Quotation

Quote for the WNS

Tell us the output, working pressure, fuel and application. An engineer replies with a model selection and a quotation.

Optional · PDF, image, CAD, Office or ZIP · up to 3 files, 8 MB each

We use your details only to answer your enquiry. The form is protected by Cloudflare Turnstile.